PPP-B-1672E
requirements for the specified type as defined in MIL-PRF-26514 when tested as specified in
5.5. For style E the static dissipative material shall conform to all requirements as defined in the
static dissipative properties test (see PPP-C-795).
3.1.2.5 Corrosivity. Anti-static cushioning material shall not cause corrosion when tested as specified in 4.5.
3.1.3 Tape. Tape shall be 2 inches (48 mm) in width and shall conform to A-A-1671, type II, class 2; ASTM D5749, type II, grade B; or ASTM D5486/D5486M, types I or II, Class 2, or types III or V.
3.1.4 Metal fasteners. Metal fasteners shall be steel staples and steel stitching wire specified for use in ASTM D5118/D5118M or 1 inch (25 mm) metal stay specified for use in ASTM D1974/D1974M, as applicable.
3.1.5 Adhesive. Adhesive for bonding of the appropriate cushioning and fiberboard components shall conform to MMM-A-1617, type I, A-A-59692, type II or other materials specified in
ASTM D5118/D5118M.
3.1.6 Recovered materials. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph 23.403 of the Federal Acquisition Regulation (FAR).
3.2 Design and construction.
3.2.1 Type I. The box, with appropriate cushioning components, shall be constructed in accordance with style A (RSC), style B (DBLCC), or style C (Modified DBLCC) designs shown in figures 1 and 2, and as specified herein (see 6.2).
3.2.1.1 Style A. Style A (RSC) boxes shall be in accordance with ASTM D5118/D5118M. The manufacturer's joint and the bottom flaps shall be stapled or stitched as specified therein. The cushioning components shall be placed in the box (see figures 1 and 2) and the top shall be taped closed with a minimum 2 x 2 inch (50 x 48 mm) strip of tape as specified in 3.1.3 or equivalent minimum closure to facilitate delivery and undamaged reopening.
3.2.1.2 Style B. Style B (DBLCC) shall be in accordance with ASTM D5118/D5118M except that the covers shall extend to one-half the depth of the tube. The lap for the tube shall be fastened inside the adjoining panel.
3.2.1.3 Style C. Style C (Modified DBLCC) shall be in accordance with ASTM D5118/D5118M except that joints for the covers and single-piece tube shall be butted and secured with metal fasteners as specified in 3.1.4 and the covers shall extend to one-half the depth of the tube.
3.2.2 Type II.
Type II boxes with appropriate cushioning components shall be constructed at the option of the
manufacturer in accordance with style D (modified TS) or style (OPF) and as specified herein
(see 6.2).
6
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business