PPP-B-1672E
TABLE II. Examination of sample unit for defects - Continued
Examine |
Defect |
CATEGORY Major Minor |
|
Style A Boxes (3.2.1.1) |
Style A boxes are not in accordance with ASTM D 5118/5118M. |
X |
|
Manufacturer's joint and bottom flange are not stapled or stitched. |
X |
||
Cushioning components are not placed inside. |
X |
||
Top is not closed to facilitate delivery. |
X |
||
Top is damaged when reopened after delivery. |
X |
||
Style B Boxes (3.2.1.2) |
Style B boxes are not in accordance with ASTM D 5118/5118M. |
X |
|
Cover does not extend to half the depth of the tube. |
X |
||
Style C Boxes (3.2.1.3) |
Style C boxes are not in accordance with ASTM D 5118/5118M. |
X |
|
Joints for covers and single-piece tubes are not butted and secured with metal fasteners. |
X |
||
Style D Boxes (3.2.2.1) |
Style D boxes are not in accordance with ASTMD 5118/5118M |
X |
|
The sleeve overlap is not stitched, stapled, or glued. |
X |
||
Style E boxes (3.2.2.2) |
Style E boxes are not in accordance with ASTM D5118/5118M |
X |
|
Style G (3.2.3) |
Style G boxes are not in accordance with ASTM D 5118/5118M. |
X |
|
Bonding of Components (3.2.5) |
Cushioning components are not adhered to box components with 45 +/- 5 percent contact area. |
X |
|
Cushioning is not centered and adhered into position in accordance with applicable figures. |
X |
||
Dimensions (3.3) |
Length, width, or depth varies by more than +1/8 inch (3 mm) from size specified. See paragraph for measurement details. |
X |
|
The center of the die-cut star cavity for type I and IV is not within 1/2 inch (13 mm) of true center. |
X |
13